Source
Report Share List favoriters

Comments

Syntax quick reference: **bold** *italic* ||hide text|| `code` __underline__ ~~strike~~ ^sup^ ~sub~

Detailed syntax guide

electrical engineering in the comments
Tags like these are what make Derpibooru awesome 😎
Background Pony #06E9
electrical engineering in the comments
ZippySqrl
HARD WERK - Merited Perfect Pony Plot Provider badge with only their own art and really hates Applejack
Office Culture - These water cooler conversations sure get heated around here.
Fifth Yacht -
Solar er - Fought against the New Lunar Republic rebellion on the side of the Solar Deity (April Fools 2023).
Preenhub - We all know what you were up to this evening~
Twinkling Balloon - Took part in the 2021 community collab.
Friendship, Art, and Magic (2020) - Took part in the 2020 Community Collab
The Magic of Friendship Grows - For helping others attend the 2020 Community Collab
Lady's Wink -
Toola Roola - For helping others attend the 2019 Community Collab

Tired Artist
BigBuggyBastage
Office Culture - These water cooler conversations sure get heated around here.
Fifth Yacht -
Grass - ...has been touched
Diamond Trophy - Are you a TAS by any chance?
Pixel Perfection - I still call her Lightning Bolt
Solar er - Fought against the New Lunar Republic rebellion on the side of the Solar Deity (April Fools 2023).
Non-Fungible Trixie -
My Little Pony - 1992 Edition
Wallet After Summer Sale -
Not a Llama - Happy April Fools Day!

Go fsck yourself
@Background Pony #28D9  
That’s an interesting aspect. I’d never really thought about whether the NEC considered the mating angle being anything but completely square/perpendicular, between the plug and socket.
 
 
The reasons I’ve always preferred the ground pin UP are as follows (sorry for the length):
 
  1. Assume a three-prong plug is inserted into a NEMA 5-15R or 5-20R duplex outlet, housed in a metal workbox & metal faceplate. Years down the road, due to vibration, poor installation, whatever, the faceplate becomes loose and falls off. Hopefully the dislodged plate will not ANY of the prongs, because the plug “should be” fully inserted. But if it does, and the ground pin is on top, gravity will help assure that it’ll the ground pin only and/or first. That “should” minimize risk of shock, even though the outlet box is in a “failed” state, and the flat on the ground prong “should” assist with holding the fallen faceplate somewhat level. Also, with a path to ground (since the faceplate is now dangling by the ground prong), even if the faceplate s the line/L, it “should” open the breaker. Yes, these are all theoretical, which is why the word “should” is in double-quotes, but I’ve fiddled with outlets, metal workboxes, EMT, etc., long enough to see the possible benefit.
     
  2. Most commercial/industrial equipment, which is what I use in my lab, assumes a ground-up outlet. This is potentially a pain when you have a molded plug where the cable is turned 90° (so it runs against the wall), and it would’ve run down (toward the floor, at about a 45° angle [from vertical]) in a ground-pin-up outlet – or it’s simply supposed to run straight down to the floor – but you’re stuck using a ground-pin-down outlet. Not a huge pain, but when you’re already running dozens of instruments on a bench, and there’s nearly a mile of cable around….
     
  3. It’s a stupid reason, I it, but I’ve found with the outlets I prefer (Leviton 20-A commercial grade, e.g. #R62-CBR20-00W), and the typical EMT routing/orientation I use, it’s MUCH easier to stuff the box (fold the wires in, after connection to the outlet) if the ground pin is up. I know, I know: “cry me a river”. 😜
     
     
    ALL THAT SAID, in a residential setting, you’re probably better off with the ground pin DOWN, because most consumer-grade electronics and accessories (extension cords, switched taps [so-called ‘power bars’], etc.) assume that’s the way your outlets are oriented. You typically don’t see metal faceplates in a residential setting these days either, outside of some basements. They’re almost exclusively insulating, non-combustible plastics now, like nylon, so the danger of the faceplate falling off and hitting a live prong is no longer present.
     
    Disclaimer: I am not an electrician by trade, though I’m fairly familiar with the NEC, performed industrial installations that have ed inspections, and my EE background should count for something (though I personally know EEs who can’t figure out how to check the oil level on their own car). tl;dr – caveat lector.
Background Pony #28D9
@HMSQuilava  
Because if it’s tugged from above it helps insure the ground pin is last to leave?  
I was going to make the reverse argument till I realized it’s more likely to be pulled up than down…
@BigBuggyBastage  
To be honest, I thought ground pin up was best practice anyways.
Little did we know the magic in the electricity gives Filly Anon the power to control and turn into electricity herself. She now calls herself: Livewire.
Background Pony #CD11
rip in pepperoni little poner
That’s gonna sting.
BigBuggyBastage
Office Culture - These water cooler conversations sure get heated around here.
Fifth Yacht -
Grass - ...has been touched
Diamond Trophy - Are you a TAS by any chance?
Pixel Perfection - I still call her Lightning Bolt
Solar er - Fought against the New Lunar Republic rebellion on the side of the Solar Deity (April Fools 2023).
Non-Fungible Trixie -
My Little Pony - 1992 Edition
Wallet After Summer Sale -
Not a Llama - Happy April Fools Day!

Go fsck yourself
@Background Pony #9949  
NEC doesn’t specify an orientation. ;)
 
Also, this is how I install ’em, when the faceplate is metal.
Background Pony #9949
Upside outlet.